Place of Origin: |
China |
Brand Name: |
JIDE |
Model Number: |
JECA-RC K |
Certification: |
CE, RoHS |
The online residual chlorine analyzer uses a German-made imported sensor, and the detection part employs a special permeation membrane technology. It has the characteristics of being resistant to chemical interference (mainly surfactants), reducing pH dependence, and being unaffected by water quality conditions. The sensor has a fast response speed, stable performance, low cost, and requires minimal maintenance, providing users with reliable and accurate data. The instrument uses an LCD display and can automatically identify measurement parameters including residual chlorine, total chlorine, chlorine dioxide, ozone, peracetic acid, hydrogen peroxide, and free bromine. It has current output and RS485 output, with freely adjustable measurement ranges, high and low limit alarm prompts, three sets of relay control switches, adjustable hysteresis range, and multiple automatic electrode calibration methods
◆ Standard industrial instruments have multiple output methods
◆ The sensor has international certifications such as CE and RoHS.
◆ Built-in temperature electrode with automatic temperature compensation
◆ Wide range of measurement options, manually switchable
◆ Fast response time, good long-term stability
◆ High cost-effectiveness, the electrodes can be used for a long time, and regular maintenance does not reduce sensitivity.
◆ Suitable for various types of water quality, with the ability to resist mechanical stress and chemical corrosion.
|
Model |
JECA-RC K |
|
Measurement parameters |
Residual Chlorine (Cl₂ + HOCl + OCl- ), Temperature |
|
Measurement method |
Clark-type Current Sensor |
|
Measurement Range |
0-5ppm |
|
Measurement Accuracy |
0.1ppm |
|
Repeatability |
±0.1 ppm |
|
Response Time |
<30s |
|
PH Influence |
Virtually negligible within the pH range of 6 to 9 |
|
Minimum Conductivity |
150 μS/cm |
|
Resolution |
0.001 ppm |
|
Supply Voltage |
(12/24)VDC |
|
Power Consumption |
0.5 W |
|
Communication Method |
RS485 (Modbus RTU) |
|
Temperature Range |
(0 ~ 50) °C |
|
Flow Rate Range |
30 ~ 60 L/hr (or 0.6 ~ 1.3 cm/s) |
|
Maximum Pressure |
0-6bar |
|
Material |
PVC |