The JDZMAS Multi-Parameter Water Quality Monitoring System is a modular flow-through cell and integrated controller-based online monitoring solution capable of connecting and collecting data from over a dozen digital and analog water quality sensors.

• High Flexibility: Modular structure adapts to diverse process installation requirements. Flexible mounting ensures high-precision measurement results.

• High Integration: Integrates multiple parameters—turbidity, residual chlorine, pH, conductivity, etc.—into a single flow cell for simplified maintenance and installation in drinking water monitoring systems.

• Effortless Maintenance: Optional cleaning and sample injection units enable automated cleaning.

• Next-Generation Controller: Android-based controller delivers a smoother, more aesthetically pleasing interface. Supports software upgrades, all digital/analog sensors, and wireless 4G communication. Features massive data storage capacity and analysis capabilities, enabling data viewing and analysis without additional computers.

Advantage

◆ Multi-channel controllers support all digital and analog sensors with flexible configuration options. Featuring a layered software architecture, they automatically pair and identify probes for plug-and-measure functionality.

◆ Equipped with a 7/10-inch TFT touchscreen and large-capacity data storage supporting up to 16GB.

◆ Runs on Linux OS with a newly designed graphical interface software. Displays historical curves for any parameter. User-friendly software design supports multiple protocol formats.

◆ Integrated remote transmission module. Standard 4G full-network wireless transmission (Bluetooth, Wi-Fi, NB-IoT optional). Supports Ethernet transmission and RS485 Modbus RTU.

Specifications

MST Controller

Operating System

Linux (MST-7, MST-10), RTOS (WQ3000)

LCD

MST-7: 7-inch color (1024*600); MST-10: 10-inch color (1280*800)

WQ3000: 4-inch color screen (800*480)

Operation Mode

Capacitive touchscreen (MST-7, MST-10), push buttons (WQ3000)

Sensor Interface

Digital sensors & analog sensors

Relay Output

MST-7: 8 x SPST (250 V AC/30 V DC, 5 A)

MST-10: 12 x SPST (250 V AC/30 V DC, 5 A)

WQ3000: 3 x SPST (250 V AC/30 V DC, 5 A)

Power Supply

MST-7: 220V@AC/(9-36)V@DC 25W

MST-10: 220V@AC/(9-36)V@DC 40W

WQ3000: 220V@AC/(9-36)V@DC 10W

Digital Output

RS232, RS485 (WQ3000 only RS485)

Expanded Network Communication

LAN \ Modbus TCP (WQ3000 not available)

Expanded Wireless Communication

Bluetooth & Wi-Fi \ 4G

Data Reading Method

USB

Data Storage

8G Flash (MST-7, MST-10), 512M Flash (WQ3000)

Product Dimensions

MST-7/MST-10 (L266mm × W93mm × H198mm)

WQ3000 (L188mm × W126mm × H160mm)

Sensors

pH Sensor

Measurement Parameters

pH, Temperature

Communication Interface

Digital RS485 (JSP101D); Analog (JSP101A)

Measurement Method

Glass Electrode Method

Range

pH: 0~14; Temperature: (0~60)°C

Accuracy

≤±0.1 pH

Repeatability

≤±0.1 pH

Resolution

0.01 pH

Response Time

≤10 s

Drift

≤±0.1 pH

Temperature Compensation

≤±0.1 pH

Temperature Range

(0~60)°C

ORP Sensor

Measurement Parameters

ORP

Communication Interface

Digital RS485 (JSP102D); Analog (JSP102A)

Measurement Method

Platinum Electrode Method

Range

ORP: (-2000~2000) mV; Temperature: (0~60) °C

Accuracy

≤±1 mV

Repeatability

≤±1 mV

Resolution

0.1 mV

Response Time

≤10 s

Drift

≤±1 mV

Turbidity Sensor

Measurement Parameters

Turbidity, Temperature

Communication Interface

Digital Output RS485

Measurement Method

90-degree infrared scattering method, flow-through cell

Range

Turbidity: (0~20) NTU; Temperature: (0~60) °C

Accuracy

≤±2%

Repeatability

≤1%

Resolution

0.001 NTU

Response Time

≤5s

Drift

≤±3% F.S.

Temperature Range

(0~60) °C

Conductivity Sensor(Two-Wire)

Measurement Parameters

Conductivity, Temperature

Communication Interface

Digital RS485 (PSE210D); Analog (PSE210A)

Measurement Method

Two-wire graphite conductivity

Range

Conductivity: 0~20000 µS/cm; Temperature: (0~60) °C

Accuracy

≤±1%

Repeatability

≤1%

Resolution

Conductivity: 0.01 µS/cm

Response Time

≤20 s

Drift

≤±1% F.S.

Temperature Compensation

≤±1% F.S.

Conductivity Sensor(Four-Wire)

Measurement Parameters

Conductivity, Temperature

Communication Interface

Digital RS485 (PSE514D); Analog (PSE514A)

Measurement Method

Four-wire graphite conductivity

Range

Conductivity: 0~200 mS/cm; Temperature: (0~60) °C

Accuracy

≤±1%

Repeatability

≤1%

Resolution

Conductivity: 0.01 µS/cm

Response Time

≤20 s

Drift

≤±1% F.S.

Temperature Compensation

≤±1% F.S.

Residual Chlorine Sensor

Model

JECA-RC C

JECA-RC K

JECA-RC RC

JECA-RC RM

Measurement Parameters

Residual Chlorine

Residual Chlorine

Residual Chlorine

Residual Chlorine

Communication Interface

Analog Signal

Digital Output RS485

Digital Output RS485

Digital Output RS485

Measurement Method

Constant Pressure Method

Clark Current Method (Imported)

Constant Pressure Method (Imported)

Membrane Method (Imported)

Range

(0–10) ppm

(0–5) ppm

(0–10) ppm

(0–10/100) ppm

Accuracy

≤±0.2 ppm

≤±0.1 ppm

≤±0.1 ppm

≤±0.1 ppm

Repeatability

≤±0.2 ppm

≤±0.1 ppm

≤±0.1 ppm

≤±0.1 ppm

Resolution

0.01 ppm

0.01 ppm

0.01 ppm

0.01 ppm

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
Choose your global partner

Are you ready to consult with an engineer about your working conditions and specific needs?

Get a Quote

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000