Place of Origin: |
China |
Brand Name: |
JIDE |
Model Number: |
JDZMAS-DW |
Certification: |
CE, RoHS |
The JDZMAS Multi-Parameter Water Quality Monitoring System is a modular flow-through cell and integrated controller-based online monitoring solution capable of connecting and collecting data from over a dozen digital and analog water quality sensors.
• High Flexibility: Modular structure adapts to diverse process installation requirements. Flexible mounting ensures high-precision measurement results.
• High Integration: Integrates multiple parameters—turbidity, residual chlorine, pH, conductivity, etc.—into a single flow cell for simplified maintenance and installation in drinking water monitoring systems.
• Effortless Maintenance: Optional cleaning and sample injection units enable automated cleaning.
• Next-Generation Controller: Android-based controller delivers a smoother, more aesthetically pleasing interface. Supports software upgrades, all digital/analog sensors, and wireless 4G communication. Features massive data storage capacity and analysis capabilities, enabling data viewing and analysis without additional computers.
◆ Multi-channel controllers support all digital and analog sensors with flexible configuration options. Featuring a layered software architecture, they automatically pair and identify probes for plug-and-measure functionality.
◆ Equipped with a 7/10-inch TFT touchscreen and large-capacity data storage supporting up to 16GB.
◆ Runs on Linux OS with a newly designed graphical interface software. Displays historical curves for any parameter. User-friendly software design supports multiple protocol formats.
◆ Integrated remote transmission module. Standard 4G full-network wireless transmission (Bluetooth, Wi-Fi, NB-IoT optional). Supports Ethernet transmission and RS485 Modbus RTU.
MST Controller
|
Operating System |
Linux (MST-7, MST-10), RTOS (WQ3000) |
|
LCD |
MST-7: 7-inch color (1024*600); MST-10: 10-inch color (1280*800) |
|
|
WQ3000: 4-inch color screen (800*480) |
|
Operation Mode |
Capacitive touchscreen (MST-7, MST-10), push buttons (WQ3000) |
|
Sensor Interface |
Digital sensors & analog sensors |
|
Relay Output |
MST-7: 8 x SPST (250 V AC/30 V DC, 5 A) |
|
|
MST-10: 12 x SPST (250 V AC/30 V DC, 5 A) |
|
|
WQ3000: 3 x SPST (250 V AC/30 V DC, 5 A) |
|
Power Supply |
MST-7: 220V@AC/(9-36)V@DC 25W |
|
|
MST-10: 220V@AC/(9-36)V@DC 40W |
|
|
WQ3000: 220V@AC/(9-36)V@DC 10W |
|
Digital Output |
RS232, RS485 (WQ3000 only RS485) |
|
Expanded Network Communication |
LAN \ Modbus TCP (WQ3000 not available) |
|
Expanded Wireless Communication |
Bluetooth & Wi-Fi \ 4G |
|
Data Reading Method |
USB |
|
Data Storage |
8G Flash (MST-7, MST-10), 512M Flash (WQ3000) |
|
Product Dimensions |
MST-7/MST-10 (L266mm × W93mm × H198mm) |
|
|
WQ3000 (L188mm × W126mm × H160mm) |
Sensors
|
pH Sensor |
|
|
Measurement Parameters |
pH, Temperature |
|
Communication Interface |
Digital RS485 (JSP101D); Analog (JSP101A) |
|
Measurement Method |
Glass Electrode Method |
|
Range |
pH: 0~14; Temperature: (0~60)°C |
|
Accuracy |
≤±0.1 pH |
|
Repeatability |
≤±0.1 pH |
|
Resolution |
0.01 pH |
|
Response Time |
≤10 s |
|
Drift |
≤±0.1 pH |
|
Temperature Compensation |
≤±0.1 pH |
|
Temperature Range |
(0~60)°C |
|
ORP Sensor |
|
|
Measurement Parameters |
ORP |
|
Communication Interface |
Digital RS485 (JSP102D); Analog (JSP102A) |
|
Measurement Method |
Platinum Electrode Method |
|
Range |
ORP: (-2000~2000) mV; Temperature: (0~60) °C |
|
Accuracy |
≤±1 mV |
|
Repeatability |
≤±1 mV |
|
Resolution |
0.1 mV |
|
Response Time |
≤10 s |
|
Drift |
≤±1 mV |
|
Turbidity Sensor |
|
|
Measurement Parameters |
Turbidity, Temperature |
|
Communication Interface |
Digital Output RS485 |
|
Measurement Method |
90-degree infrared scattering method, flow-through cell |
|
Range |
Turbidity: (0~20) NTU; Temperature: (0~60) °C |
|
Accuracy |
≤±2% |
|
Repeatability |
≤1% |
|
Resolution |
0.001 NTU |
|
Response Time |
≤5s |
|
Drift |
≤±3% F.S. |
|
Temperature Range |
(0~60) °C |
|
Conductivity Sensor(Two-Wire) |
|
|
Measurement Parameters |
Conductivity, Temperature |
|
Communication Interface |
Digital RS485 (PSE210D); Analog (PSE210A) |
|
Measurement Method |
Two-wire graphite conductivity |
|
Range |
Conductivity: 0~20000 µS/cm; Temperature: (0~60) °C |
|
Accuracy |
≤±1% |
|
Repeatability |
≤1% |
|
Resolution |
Conductivity: 0.01 µS/cm |
|
Response Time |
≤20 s |
|
Drift |
≤±1% F.S. |
|
Temperature Compensation |
≤±1% F.S. |
|
Conductivity Sensor(Four-Wire) |
|
|
Measurement Parameters |
Conductivity, Temperature |
|
Communication Interface |
Digital RS485 (PSE514D); Analog (PSE514A) |
|
Measurement Method |
Four-wire graphite conductivity |
|
Range |
Conductivity: 0~200 mS/cm; Temperature: (0~60) °C |
|
Accuracy |
≤±1% |
|
Repeatability |
≤1% |
|
Resolution |
Conductivity: 0.01 µS/cm |
|
Response Time |
≤20 s |
|
Drift |
≤±1% F.S. |
|
Temperature Compensation |
≤±1% F.S. |
|
Residual Chlorine Sensor |
||||
|
Model |
JECA-RC C |
JECA-RC K |
JECA-RC RC |
JECA-RC RM |
|
Measurement Parameters |
Residual Chlorine |
Residual Chlorine |
Residual Chlorine |
Residual Chlorine |
|
Communication Interface |
Analog Signal |
Digital Output RS485 |
Digital Output RS485 |
Digital Output RS485 |
|
Measurement Method |
Constant Pressure Method |
Clark Current Method (Imported) |
Constant Pressure Method (Imported) |
Membrane Method (Imported) |
|
Range |
(0–10) ppm |
(0–5) ppm |
(0–10) ppm |
(0–10/100) ppm |
|
Accuracy |
≤±0.2 ppm |
≤±0.1 ppm |
≤±0.1 ppm |
≤±0.1 ppm |
|
Repeatability |
≤±0.2 ppm |
≤±0.1 ppm |
≤±0.1 ppm |
≤±0.1 ppm |
|
Resolution |
0.01 ppm |
0.01 ppm |
0.01 ppm |
0.01 ppm |
Are you ready to consult with an engineer about your working conditions and specific needs?